TESTER

 

 
* 4300 COUNT LCD
* Shock-proof rubber holster with probe holders
* Compact body with Tilt Stand
* Auto Ranging
* Auto Hold
* Diode & Continuity check
* Comes with dust-proof soft case
       
........................................................................................................................................................................................................
........................................................................................................................................................................................................


●Dimensions : 148(L)×71(W)×37(H) o
●Weight : 220g (including holster)
.......................................................................................................................................................................................................
DC Voltage
Range Resolution Accuracy Max. Input
400.0mV 0.1mV ±0.5% rdg.±1 dgt. 600 V
4.000V 1mV
40.00V 10mV ±0.75% rdg.±1 dgt.
400.0V 100mV
600V 1 V
AC Voltage
Range Resolution Accuracy Max. Input
4.000V 1mV ±1.0% rdg.±5 dgt. 600 V
40.00V 10mV
400.0V 100mV
600V 1 V
Resistance (Ω)
Range Resolution Accuracy Max. Input
400.0Ω 0.1 ohm ±0.75% rdg.±2 dgt. 600 V
4.000kΩ 1 ohm ±0.75% rdg.±1 dgt.
40.00kΩ 10 ohm
400.0kΩ 100 ohm
4.000MΩ 1K ohm ±2% rdg.±1 dgt.
40.00MΩ 10K ohm ±5% rdg.±2 dgt.
Continuity Check
Range Resolution Beeper sound Max. Input
400Ω 0.1 ohm <50±25Ω 600 V
Diode Testing
Range Resolution Accuracy Max. Input
2.00V 10 mV ±1% rdg.±1 dgt. 600 V
DC Current
Range Resolution Accuracy Max. Input
400.0μA 0.1 micro A ±1% rdg.±2 dgt. 400 mA
4000μA 1 micro A
40.00mA 10 micro A
400.0mA 0.1 mA
10.00 A 10 mA ±2% rdg.±2 dgt. 10 A
AC Current
Range Resolution Accuracy Max. Input
400.0μA 0.1 micro A ±2% rdg.±20 dgt. 400 mA
4000μA 1 micro A ±2% rdg.±5 dgt.
40.00mA 10 micro A ±2% rdg.±20 dgt.
400.0mA 0.1 mA ±2% rdg.±5 dgt.
10.00 A 10 mA ±2.5% rdg.±20 dgt. 10 A


 
 